Vertical expansion joints in SL masonry veneers must be done as follows:
- near building corners,
- at a spacing of 6-8 meters in long sections of masonry
- in extension from window framing for large windows and doors
Proven joint sealing methods are:
- leaving vertical joints open
- joint sealant complying with DIN 18540
- joint filler made of foam rubber strips