Processing Masonry

Exposed Masonry

Vertical expansion joints in SL masonry veneers must be done as follows:

  • near building corners,
  • at a spacing of 6-8 meters in long sections of masonry
  • in extension from window framing for large windows and doors

Proven joint sealing methods are:

  • leaving vertical joints open
  • joint sealant complying with DIN 18540
  • joint filler made of foam rubber strips